Jul 6, 2010
Have you ever experienced weld puddle shift? Have you ever wondered why ASME BPE limits sulfur for tube and fittings to .005% to .017%? Take a look at these videos, and you’ll understand why. Clip 1 shows matched sulfur of .008% on both weld pieces. Clip 2 shows mismatched sulfur of .002% welded to .014%. Notice how the weld pool tracks off-center of...