Standard Drum Pump Metering System
The standard drum pump metering system from Standard Pump is engineered to dispense and meter materials from drums, totes, and kettles. The system includes a 3-A compliant sanitary transfer pump, in addition to one of many types of flow meters available. The meters cater to a truly hygienic design and accurate performance.
A two-piece design enables operators to quickly disassemble and clean internal components. The proven flow meter and pump system is an excellent choice for metering low viscosity liquids.
Models
- With flow meter (electric)
- With flow meter (air)
- With batch control (electric)
- With batch control (air)
- With ultra mass batch control (electric)
- With ultra mass batch control (air)
APPLICATIONS
Standard Pump offers many different metering combinations to cover the widest number of applications possible. Whether you are looking for mass metering, magnetic metering, or turbine style metering, there is a batching or metering system to meet your needs. Applications include milk, filtered juice, water, pie fillings, beer, filtered wine, shampoo, and conditioner.
WORKING PRINCIPLE
These drum pump metering systems combine the proven Standard Pump tote, drum, kettle, or tank unloading pumps with a variety of different metering options for a system that provides reliable and repeatable metering and batching.
FEATURES
Ultra Mass Batch Control (Electric)
Made entirely of 3-A (TPV) certified components and FDA compliant materials, the Ultra Mass Batch Control (Electric) is low shear and suitable for conductive and non-conductive solutions. It's designed with easy-to-clean Tri-Clamp® fittings. Interface capabilities include HART, PROFIBUS, PA/DP, and FOUNDATION Fieldbus, with quick setup menus for in-field commissioning.
Ultra Mag Batch Control (Electric)
The 3-A compliant Ultra Mag Batch Control (Electric) features a large graphic, multi-language display with both standard or metric units of measure available for measuring volume. It's designed to be low shear and easy-to-clean with Tri-Clamp® fittings. Non-invasive measurement offered.
FLOW METER AND PUMP SYSTEM (ELECTRIC)
The Flow Meter And Pump System (Electric) comes with Tri-Clamp® fittings. It's hygienic, 3-A compliant design makes it easy to clean. The turbine paddle wheel viscosity goes up to 100 cps (mPas), and there is a remote mount meter display included.
ULTRA MASS BATCH CONTROL (AIR)
Made entirely of 3-A (TPV) components and FDA compliant materials, the Ultra Mass Batch Control (Air) is low shear and suitable for conductive and non-conductive solutions. It's designed with easy-to-clean Tri-Clamp® fittings. Interface capabilities include HART, PROFIBUS, PA/DP, and FOUNDATION Fieldbus, with quick setup menus for in-field commissioning.
Ultra Mag Batch Control (Air)
The 3-A compliant Ultra Mag Batch Control (Air) features a large graphic, multi-language display with both standard or metric units of measure avaliable for measuring volume. It's designed to be low shear and easy-to-clean with Tri-Clamp® fittings. Non-invasive measurement offered.
Flow Meter and Pump System (Air)
The Flow Meter And Pump System (Air) comes with Tri-Clamp® fittings. It's hygienic, 3-A compliant design makes it easy to clean. The turbine paddle wheel viscosity goes up to 100 cps (mPas), and there is a remote mount meter display included.
TECHNICAL DATA
Ultra mass batch control (Electric)
Motor Drive | TEFC (IP54) variable speed |
Maximum Flow Rate | 8 gpm |
Maximum Viscosity Range | 25,000 cps (mPAS) |
Immersion Length | 39 inch |
Accuracy | +/– 0.30% of reading |
Maximum Temperature | 185°F |
Bag Liner Series | Optional pump intake design available for applications with hygienic liners |
Ultra Mag Batch Control (Electric)
Motor Drive | TEFC (IP54) variable speed |
Maximum Flow Rate | 10 gpm |
Maximum Viscosity Range | 25,000 cps (mPAS) |
Immersion Length | 39 inch |
Accuracy | +/– 0.2% of reading (+/– 0.5% repeatability) |
Maximum Temperature | 212°F |
Bag Liner Series | Optional pump intake design available for applications with hygienic liners |
Flow Meter and Pump System (Electric)
Motor Drive | TEFC (IP54) variable speed |
Maximum Flow Rate | 27 gpm |
Maximum Viscosity Range | 100 cps (mPas) |
Immersion Length | 39 inch |
Accuracy | +/– 0.50% (+/– 0.10% repeatability) |
Maximum Temperature | 175°F |
Ultra Mass Batch Control (Air)
Motor Drive | Air motor, 2.0 HP |
Maximum Flow Rate | 8 gpm |
Maximum Viscosity Range | 25,000 cps (mPAS) |
Immersion Length | 39 inch |
Accuracy | +/– 0.30% of reading |
Maximum Temperature | 185°F |
Bag Liner Series | Optional pump intake design available for applications with hygienic liners |
Ultra Mag Batch Control (Air)
Motor Drive | Air motor, 2.0 HP (1,5 KW) |
Maximum Flow Rate | 10 gpm |
Maximum Viscosity Range | 25,000 cps (mPAS) |
Immersion Length | 39 inch |
Accuracy | +/– 0.2% of reading (+/– 0.5% repeatability) |
Maximum Temperature | 212°F |
Bag Liner Series | Optional pump intake design available for applications with hygienic liners |
Flow Meter and Pump System (Air)
Motor Drive | Air motor, 1/2 HP (370 W) |
Maximum Flow Rate | 20 gpm |
Maximum Viscosity Range | 100 cps (mPas) |
Immersion Length | 39 inch |
Accuracy | +/– 0.50% (+/– 0.10% repeatability) |
Maximum Temperature | 175°F |
Product Resources
See all resources by Standard PumpLiterature
- Standard Batch Control Systems And Flow Meters Brochure
- Standard Ultra Mag Series Manual
- Standard Ultra Mass Series Manual
- Standard Air Ultra Mag Batch Control System Data Sheet
- Standard Air Ultra Mag Batch Control System Parts List
- Standard Air Ultra Mass Batch Control System Data Sheet
- Standard Air Ultra Mass Batch Control System Parts List
- Standard Electric Ultra Mass Batch Control System Data Sheet
- Standard Electric Ultra Mass Batch Control System Parts List
- Standard Electric Ultra Mag Batch Control System Data Sheet
- Standard Electric Ultra Mag Batch Control System Parts List
- Standard Air Flow Meter System Data Sheet
- Standard Electric Flow Meter Systems Data Sheet
- Standard Flow Meter And Pump System Parts List
- Standard Sanitary Pumps 3-A Certificate
Blog Posts
Create a MyCSI Dashboard to save resources for quick reference, track orders, and talk with experts.
Create a MyCSI Dashboard to save resources for quick reference, track orders, and talk with experts.
It only takes a minute.
Sign in
Sign in to save resource to your dashboard.
Literature for Standard Drum Pump Metering System have been saved to your dashboard!
Literature for Standard Drum Pump Metering System are already in your dashboard.